Pro-face PS-3700A User Manual Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 10
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
COM1
VM Unit
GP2000-VM41
V M U n i t
CC-Link Unit
CA7-CCLALL/EX-01
C C - L i n k U n i t
DeviceNet Slave Unit
CA6-DNSALL/EX-01
DeviceNet Slave Unit
With LT3000With LT3000
Adding a display while
avoiding extra cost.
Control, display, and operation are
performed by one piece of equipment
to cut down on equipment and keep
cost at a minimum.
Possible future system
expansion.
LT3000 SERIES is for those who desire
〔B〕System Maker was entrusted by a client to introduce IT on site. However, building
a system using a display and PLC requires costs for hardware that exceed the budget.
That is why this manufacturer decided to adopt LT-3300S. This controller not only
includes display, operation, and control functions all in one piece of equipment, but
with the Serial I/F included, direct connection to equipment on site is also possible
even without a PLC. Furthermore, it is possible to send information obtained on site
to a main computer thanks to the Ethernet I/F mounted. A system was developed
which saves on costs using the smallest possible unit.
A small-sized information gathering system
can be realized with LT-3300S,
without installing a PLC.
Example
Solutions
EX Modules
8-Point Input Module
16-Point Input Module
8-Point Relay Output Module
16-Point Relay Output Module
8-Point Sink Output Module
16-Point Sink Output Module
8-Point Source Output Module
16-Point Source Output Module
4-Point Input/4-Point Output Module
2-ch Analog Input Module
Thermocouple Pt100 Input /
  1-ch Analog Output Module
2-ch Analog Input/
 1-ch Analog Output Module
1-ch Analog Output Module
LT3000SERIES
All-in-one display/operation function on controller
GP-Pro EX
G P 3 0 0 0 S E R I E S S y s t e m D e s i g n
CF Card Interface
(TYPE-II SLOT)
PCMCIA Slot
CF Card
CA3-CFCALL/128MB-01
CA3-CFCALL/256MB-01
CA3-CFCALL/512MB-01
CA6-CFCALL/1GB-01
CF Card Adapter
GP077-CFAD10
Sound Out Interface
(Terminal Connector)
Ethernet Interface
(10BASE-T/100BASE-TX)
Expansion Unit Interface
Twisted-pair cable
(Commercial type)
Speaker
(Commercial type)
Video Camera
(Commercial type)
PL Series or other
IPC, or PLC.
Industrial HUB
(Commercial type)
PC
(Commercial type)
USB Host Interface (Host)
USB-to-IEEE1284 Conversion Cable
(Commercial type)
USB Cable (5m) or Commercial type
FP-US00
VM Unit Interface
USB Front Cable (1m)
CA5-USBEXT-01
PROFIBUS Slave Unit
CA5-PFSALL/EX-01
USB Hub
(Commercial type)
Printer
(Commercial type)
Various parts including I/O Unit,
display, LED, Sensor, Switch, etc.
FLEX NETWORK I/O Unit,
FLEX NETWORK Analog Unit, etc.
Printer
(Commercial type)
Bar-Code Reader
(Commercial type)
GP-3500T/GP-3510T/GP-3550T/GP-3560T/GP-3600T/GP-3650T Only
DIO Connector
CA6-DIOCNALL-01
VM Unit
GP2000-VM41
USB-Serial (RS-232C) Conversion Cable (40cm)
CA6-USB232-01
DeviceNet Slave Unit
CA6-DNSALL/EX-01
CC-Link Unit
CA7-CCLALL/EX-01
USB Transfer Cable (2m)
CA3-USBCB-01
Screen Editor
GP-Pro EX V2.10
EX-ED-V21
Ethernet Interface (10BASE-T/ 100BASE-TX)  Not supported by GP-3301S/GP-3301L/GP-3302B.
USB Interface (Host)
USB Port
Ethernet Port
PC
(Commercial type)
Video Input Interface
(V-IN)
Audio Input Interface
(L-IN/MIC)
Modem
(Commercial type)
MIC
(Commercial type)
DIO Interface
FLEX NETWORK Interface
FLEX NETWORK Connector
CA6-FNCNALL-01
Interface for M Class
Edit Mode peripherals
Interface for M Class
DIO Cable
(Prepared by the user)
FLEX NETWORK
Communication Cable
FN-CABLE2010-31-MS (10m)
FN-CABLE2050-31-MS (50m)
FN-CABLE2200-31-MS (200m)
For connectable devices, please refer to OtasukePro!
(http://www.pro-face.com/otasuke/).
Not available with 3.8inch/
GP-3302B.
PROFIBUS Slave Unit
CA5-PFSALL/EX-01
PROFIBUS Slave Unit
16-input Sink/Source and16-point
transistor output Sink type
FN-XY16SK41
16-pin input Sink/Source
and 16-point transistor
output Source type
FN-XY16SC41
4-channel Analog/
Digital Conversion Unit
FN-AD04AH11
2-channel Analog/
Digital Conversion Unit
FN-AD02AH41
32-pin input Sink/
Source and
32-point transistor
output Sink type
FN-XY32SKS41
*
1. Please contact our sales staff.
Ethernet
Serial
DIO,
Analog
Inverter
Temperature
Controller
Server PC
LT-3300S/
LT-3300L
LT-3301L
5.7
inch
QVGA
LT3300-L1-D24-K
Sink Output Type
LT3300-L1-D24-C
Source Output Type
LT-3300S/L
5.7
inch
QVGA
DC24V
DC24V
LT3300-S1-D24-K
Sink Output Type
LT3300-S1-D24-C
Source Output Type
DC24V
DC24V
DC24V
DC24V
16-point inputs, 16-point outputs
Interface for Pro-face’s EX Modules
(Up to three EX modules can be connected)
Monochrome LCD
320 x 240 pixels
Black and White 16 Shades
I/F
COM×1 / Ethernet×1 / AUX Unit I/F×1 / USB×1 / EX Module I/F×1
I/F
COM×1 / AUX Unit I/F×1 / USB×1 / EX Module I/F×1
16-point inputs, 16-point outputs
Interface for Pro-face’s EX Modules
(Up to three EX modules can be connected)
STN Color LCD(LT-3300S)/Monochrome LCD(LT-3300L)
320 x 240 pixels
4,096 Colors(LT-3300S)/Black and White16 Shades(LT-3300L)
LT3301-L1-D24-K
Sink Output Type
LT3301-L1-D24-C
Source Output Type
COM2
Main Network
O p t i o n s
With Serial I/F, GP can be connected to various PLC.
Contact us for more details.
Manufacturer aims for low-cost system development
B
All 13 types of I/O units may be expanded
into 3 modules maximumL T-3201A c an b e
expanded into 2 modules maximum). Flexible options
for equipment and function upgrades.
B
32-point input Sink/
Source type
FN-X32TS41
FLEX NETWORK Unit
*
2. UL508, UL60950-1, ANSI/ISA-12.12.01-2000, UL1604, CSA-C22.2 No.14-95M(c-UL approval), CSA-C22.2 No.213-M1987(c-UL approval), CAN/CSA C22.2 No.60950-1-03(c-UL approval, EN55011 Class A and EN61000-6-2
*
3. UL508, UL60950-1,
ANSI/ISA-12.12.01-2000, CSA-C22.2 No.142-M1987(c-UL approval), CSA-C22.2 No.213-M1987(c-UL approval), CAN/CSA C22.2 No.60950-1-03(c-UL approval), EN55011 Class A and EN61000-6-2
*
4. UL508, UL1604, CAN/CSA-C22.2,Nos.142,and
213-M1987, EN55011 Class A and EN61000-6-2
*
5. UL508, CAN/CSA-C22.2, No.1010.1, EN55011 ClassA and EN61000-6-2
*
6. UL508, CAN/CSA-C22.2,No.1010.1-92.(c-UL approval), EN55011 Class A and EN61000-6-2
*
3. LT-3201A is not equipped with Serial I/F.
*
4. Analog input/output and temperature input is possible with the EX module.
*
5. Connection driver is updated as needed.
R e s p o n s e s o f t w a r e
G r a p h i c L o g i c C o n t r o l l e r s
*
2
*
5
*
5
*
5
*
5
*
6
*
3
*
3
*
4
*
1
*
1
*
1
*
1
*
4
*
5
*
3
*
1
*
1
3.8
inch
QVGA
LT-3201A
12-point inputs, 6-point outputs
Interface for Pro-face’s EX Modules
(Up to two EX modules can be connected)
Monochrome Amber/ Red LCD
320 x 240 pixels
Black and White 8 Shades
I/F
AUX Unit I/F×1 / USB×1 / EX Module I/F×1
DC24V
LT3201-A1-D24-K
Sink Output Type
LT3201-A1-D24-C
Source Output Type
DC24V
*
2
*
2
*
1. UL508, ANSI/ISA-12.12.01-2007 Rev. 1 or later, CSA-C22.2 No.142-M1987, CSA-C22.2 No.213-M1987, EN55011 Class A, EN61000-6-2
*
2. UL508, ANSI/ISA-12.12.01-2000 Rev. B or later, CSA-C22.2 No.142-M1987, CSA-C22.2 No.213-M1987, EN55011 Class A, EN61000-6-2
*
1
*
1
Not supported by GP-3301S/
GP-3301L/GP-3302B.
*
1
Not available with 3.8inch.
*
1
*
1
Not supported by 3.8inch/5.7 inch.
*
1
*
1
*
1
5 6
Page view 3
1 2 3 4 5 6 7 8 9 10

Comments to this Manuals

No comments