Chapter 4 Installation and Wiring
4-7
4.2 Wiring Precautions
This section describes the procedures and precautions for wiring power cords.
4.2.1 Connecting the Power Cord
If the power connector is the following type, please read the following.
If the power connector is the following type, please read from page 4-11.
WARNING
HAZARD OF ELECTRIC SHOCK
Prior to connecting the GP unit's power cord terminals to the power terminal block, confirm that the
GP unit's power supply is completely turned OFF, via a breaker, or similar unit.
Supplying a power voltage other than that specified will damage the power source and the GP unit.
Since there is no power switch on the GP unit, be sure to attach a breaker-type switch to its power
cord.
When the FG terminal is connected, be sure the wire is grounded.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
When the FG terminal is connected, be sure the wire is grounded. Not grounding the
GP unit will result in excess noise and vibration.
The SG and FG terminals are connected internally in the GP unit.
When connecting the SG wire to another device, be sure that the design of the
system/connection does not produce a shorting loop.